hotline

15895191047   

image.png


Contact us

盐城市创惠电热科技有限公司

张天:15895191047 

杜文华:13961983587

许中勇:13962067633 

邮箱:1249802206@qq.com

地址:江苏省盐城市盐都区顺丰物流园2号楼403室

网址:   www.chdrkj.com  


taiwanThe original manufacturer of heat conducting oil furnace

Your current location: Home >> Products >> taiwanHeat conducting oil furnace

taiwanThe original manufacturer of heat conducting oil furnace

  • Taxonomy:taiwanHeat conducting oil furnace

  • Click times:
  • Date of release:2019/06/17
  • Specifications:
  • Type:
  • inquiry
  • introduce


Because pure smokeless re-energy-saving technology uses the power-saving system of PID frequency conversion and ABM, which saves 40% of the power compared with traditional boilers, and the volatile can realize more than 90% combustion and utilization, while the volatile of traditional boilers only burns out about 78%, and 22% of the smoke and dust are discharged into the atmosphere. The pure smokeless re-energy-saving swirl technology makes the ash combustion rate reach 97%, while the traditional boiler cinder combustion rate is only about 80%. It is for these reasons that the pure smokeless energy-saving technology can raise the furnace temperature from 1200 to about 1500 degrees C, thus realizing power saving and coal saving.

The heat conducting oil furnace (organic heat carrier heating furnace) uses coal, heavy oil, light oil, combustible gas and other combustible materials as fuel and heat conducting oil as heat carrier. The circulating oil pump is used to force the liquid phase circulation, and the heat energy is conveyed to the heating equipment, then returned to the reheated DC special industrial furnace.

Abnormal condition of circulating pump

When the current of the circulating pump is lower than the normal value, it shows that the efficiency of the circulating pump decreases and the flow rate decreases. The price of the heat conducting oil furnace may be the fouling blockage of the heating pipeline, which should be cleaned.

If the circulating pump pressure remains unchanged and the current increases while the flow rate decreases, the heat conducting fluid will deteriorate and the viscosity will increase, so it should be replaced or regenerated in time. If the water-bearing or decomposed gas in the newly heated conductive fluid is not excluded in the system, the vent valve should be opened immediately to discharge the gas.

Circulating pump current decreases, outlet pump pressure returns to zero, indicating that the pump does not supply oil when idling. It may be oil vaporization, find out the cause of vaporization and take measures; if the filter is blocked and the circulating pump is emptied, the by-pass cleaning filter should be opened immediately; if the water content of the new heat conducting fluid or the gas decomposed by water is not eliminated in the system, the exhaust valve should be opened immediately.


The address of this article:http://enchdrkj.mycn86.cn/product/640.html

Key word:

Recently browse:

Related products:

Related news:

Corporate name

Zhang Tian:15895191047 

Du Wenhua:13961983587

Xu Zhongyong:13962067633 

mailbox:1249802206@qq.com

address:Shunfeng Logistics Park, Yandu District, Yancheng City, Jiangsu Province

Website:   www.chdrkj.com  

Bottom navigation

Home      About      Product

News      Case      Heating

Message      Contact

Focus on us

manager zhangAlibaba
  • Service
  • number
    15895191047
  • Message
  • Online Service
    Please leave a message for us
    Please input the message here, and we will contact you as soon as possible.
    name
    Contacts
    Telephone
    Telephone
    mailbox
    mailbox
    address
    address